DraftStoppa Installation Instructions
Standard
Installation for Exhaust Fans: Step by Step
Step
One:
Place one unassembled half body on a flat surface - (Figure 1)

Step
Two:
Slide
the other unassembled half body into the corresponding side slots
until they click into place. Ensure that the two central ridge locking
pins are clicked together (Figure 2)

Step Three:
Fit the two lids by inserting one lid pin into the corresponding
closed hole on the body and then pushing the other pin through the
corresponding slot to lock. It should now pivot freely.
Step
Four:
Repeat for the other half.
Step Five:
Take the assembled unit into the ceiling space and place it over
the top of the ceiling exhaust fan.

Step Six:
Place fan power lead in cut-out hole.
Step Seven:
Test operate the fan and ensure that the flaps operate smoothly.
3
in 1 Heat/Light/Fan Installation: Please Read Carefully
Wiring Modifications Safety Note
'DraftStoppa'
is adaptable to "3-in-1 heater, exhaust fan and light ceiling
units" that vent directly into the roof cavity such as the
tastics. It will not work with units that vent directly to an outside
opening via a duct.
It
is important that when installing the 'DraftStoppa' that you read,
understand and follow the installation instructions supplied by
the various "3- i -1 heater, exhaust fan and light ceiling
unit" manufacturers. When installing the 'DraftStoppa' over
a ceiling exhaust fan / heating combination unit it is important
to ensure that the 'DraftStoppa' is not over heated. This can be
achieved by modifying the wall switch wiring so that the heating
switches are in series with the fan switch.
The
heating switches are to be on the load side of the fan switch. It
is especially important that you follow the ventilation and clearance
requirements and ensure that the unit is installed in accordance
with AS/NZS 3000:2000 wiring instructions and ensure that the heating
and fan switches are wired in series so that the fan must always
operate when the heating lamps are operating. See wiring diagram
below.

Please
Note: These instructions are reproduced for the convenience of our
customers from information supplied by the manufacturer.
Return
to DraftStoppa Home Page.
Call
Enviro-Friendly today on (02) 6282 6266, and find out how we can
help you
"Save water, save energy, save
money, and save the environment."
For
enviro-friendly tips and news, be sure to
and please, tell your friends about us!
|